capillary tube 4,3 x 0,8 mm | round mat distributor pipe 20 x 2,0 mm

The ready-made capillary tube mat which is clicked into a perforated insert foil. Due to the protected position of the capillaries in the foil the FOLIMAT can be walked on without any risk of damage even before the floor covering is placed or laid. 

This capillary tube mat is predestined for filling on flat surfaces in floor, wall and ceiling areas. The FOLIMAT is particularly often used for underfloor heating systems and can be laid directly on a load-bearing substrate of screed, wood or dry construction elements. As a thin-layer underfloor heating a construction height of only 8-10 mm is already sufficient. This makes it excellently suitable for renovation.

FOLIMAT heating and cooling mat  FSB 20.00 | 20.11 | 20.20 | 20.02

 

FSB 20.00  
with open mat distributor pipes
for welding
 
FOLIMAT FSB 20

capillary tube mat

in perforated foil insert

Detail FOLIMAT FSB 20

push-lock connections

Designation FSB 20.00 FSB 20.11 FSB 20.20 FSB 20.02
Description with open
mat distributor pipes

with 2
lateral push-lock-connections

with 2
push-lock-connections
on the left

with 2
push-lock-connections
on the right

Pictogram FSB 20.00 Clina push-lock connection pictogram FSB 20.11 Clina push-lock connection pictogram FSB 20.20 Clina push-lock connection pictogram FSB 20.02 Clina push-lock connection pictogram

field of application

  • floor|onto cement screed or floating screed
  • floor|onto wooden or dry screed subfloors
  • ceiling and wall|for gluing to and afterwards filling on load-bearing substrates

technical data

MATERIAL/COLOUR mat distributor pipe and capillary tube: Polypropylene (PP-R) recyclable/blue;
insert foil: Polystyrene/black
MAT DISTRIBUTOR PIPE 20 x 2,0 mm, round
CAPILLARY TUBE MAT 4,3 x 0,8 mm
DISTANCE  A 20 mm
LENGTH  L 600‐6000 mm in 10-mm steps
WIDTH  B 300 mm/600 mm
CONNECTION TYPE with open mat distributor pipes/with 2 push-lock-connections 10 mm or 15 mm
SPECIFIC WEIGHT approx. 700 g/m² capillary tube surface
SPECIFIC VOLUME OF WATER 0,320 l/m² capillary tube surface
SPECIFIC  TOTAL WEIGHT approx. 1020 g/m² capillary tube surface
PRESSURE STAGE PN 10
MAX. RECOMMENDED OPERATING PRESSURE 4 bar
MAX. ALLOWED HEATING TEMPERATURE 60 °C